# Licensed under a 3-clause BSD style license - see LICENSE.rst
"""FLITECAM Reduction pipeline steps"""
import os
import re
from astropy import log
from sofia_redux.pipeline.sofia.sofia_exception import SOFIAImportError
try:
import sofia_redux.instruments.flitecam
except ImportError:
raise SOFIAImportError('FLITECAM modules not installed')
from sofia_redux.pipeline.reduction import Reduction
from sofia_redux.pipeline.sofia.forcast_reduction \
import FORCASTReduction
from sofia_redux.pipeline.sofia.parameters.flitecam_parameters \
import FLITECAMParameters
from sofia_redux.toolkit.utilities.fits import hdinsert
__all__ = ['FLITECAMReduction']
[docs]
class FLITECAMReduction(FORCASTReduction):
"""
FLITECAM reduction steps.
Primary image reduction algorithms are defined in the flitecam
package (`sofia_redux.instruments.flitecam`). Calibration-related
algorithms are pulled from the `sofia_redux.calibration` package, and
some utilities come from the `sofia_redux.toolkit` package. This
reduction object requires that all three packages be installed.
This reduction object defines a method for each pipeline
step, that calls the appropriate algorithm from its source
packages.
Attributes
----------
prodtype_map : dict
Maps the pipeline step to a product type, to assign
to the PRODTYPE key. Keys are pipeline step function names.
prodnames : dict
3-letter file type code, to assign to the output of a pipeline
step. Keys are the product types (as defined in prodtype_map).
step_map : dict
Inverse of the prodtype_map, for looking up pipeline
step names from product types. Keys are the product types.
prodtypes : list
List of product types, corresponding to the currently
loaded recipe. This list is populated whenever the recipe
attribute is set.
cal_conf : dict-like
Flux calibration and atmospheric correction configuration,
as returned from the pipecal `pipecal_config` function.
"""
def __init__(self):
"""Initialize the reduction object."""
super().__init__()
# descriptive attributes
self.name = 'Redux'
self.instrument = 'FLITECAM'
self.mode = 'any'
self.data_keys = ['File Name', 'OBJECT', 'OBSTYPE',
'AOR_ID', 'MISSN-ID', 'DATE-OBS',
'INSTCFG', 'INSTMODE',
'SPECTEL1', 'SPECTEL2',
'SLIT', 'ALTI_STA', 'ZA_START',
'EXPTIME', 'DTHINDEX', 'NODBEAM']
self.pipe_name = "FLITECAM_REDUX"
self.pipe_version = \
sofia_redux.instruments.flitecam.__version__.replace('.', '_')
# associations: this will be instantiated on load
self.parameters = None
# product type definitions for FLITECAM steps
self.prodtype_map = {
'check_header': 'raw',
'correct_linearity': 'linearized',
}
self.prodnames = {
'raw': 'RAW',
'linearized': 'LNZ',
}
# invert the map for quick lookup of step from type
self.step_map = {v: k for k, v in self.prodtype_map.items()}
# this will be populated when the recipe is set
self.prodtypes = []
# default recipe and step names
self.recipe = ['check_header', 'correct_linearity']
self.processing_steps = {
'check_header': 'Check Headers',
'correct_linearity': 'Correct Nonlinearity',
}
# reduction information
self.output_directory = os.getcwd()
# reference file and obsmode configuration
self.calres = {}
# photometric flux calibration information
self.cal_conf = None
[docs]
def getfilenum(self, filename):
r"""
Get the file number from a file name.
Returns UNKNOWN if file number can't be parsed.
Parameters
----------
filename : str
File name to parse. Raw filenames (not starting with
F[\d]+) are assumed to be \\*[_-][filenum].?.fits.
Processed filenames are assumed to be \\*_[filenum].fits.
Returns
-------
str or list
File number(s), formatted to 4 digits.
"""
basename = os.path.basename(filename)
try:
if re.match(r'^F\d+', basename):
numstr = re.split('[_.]', basename)[-2]
elif basename.endswith('.a.fits'):
numstr = re.split('[_.-]', basename)[-3]
else:
numstr = re.split('[_.-]', basename)[-2]
try:
filenum = '{0:04d}'.format(int(numstr))
except ValueError:
filenum = ['{0:04d}'.format(int(n))
for n in numstr.split('-')]
except (ValueError, IndexError):
filenum = 'UNKNOWN'
return filenum
[docs]
def getfilename(self, header, update=True, prodtype='RAW',
filenum='UNKNOWN'):
"""
Create an output filename from an input header.
Parameters
----------
header : fits.Header
Header to create filename from.
update : bool, optional
If set, FILENAME key will be added or updated
in the header.
prodtype : str, optional
Three letter product type designator.
filenum : str or list, optional
List of file numbers to concatenate for filename.
Returns
-------
str
The output name.
"""
# get flight number
missn = header.get('MISSN-ID', 'UNKNOWN')
flight = missn.split('_')[-1].lstrip('F')
try:
flight = 'F{0:04d}'.format(int(flight))
except ValueError:
flight = 'UNKNOWN'
# get AOR_ID
aorid = header.get('AOR_ID', 'UNKNOWN').replace('_', '')
# get filter
spectel = header.get('SPECTEL1', 'UNKNOWN').replace('_', '')
# get config
instcfg = header.get('INSTCFG', 'UNKNOWN').strip().upper()
if instcfg in ['SPECTROSCOPY', 'GRISM']:
inst = 'FC_GRI'
else:
inst = 'FC_IMA'
# concatenate file numbers
filenumstr = self._catfilenum(filenum)
# join outname
outname = '_'.join([flight, inst, aorid, spectel,
prodtype, filenumstr]).upper()
outname = outname + '.fits'
if update:
hdinsert(header, 'FILENAME', outname, comment='File name')
return outname
[docs]
def load(self, data, param_class=None):
"""
Load input data to make it available to reduction steps.
The process is:
- Call the parent load method to initialize data
reduction variables.
- Use the first loaded FITS header to determine and load
the configuration.
- Use the loaded configuration and the product type in the
base header to determine the data processing recipe.
- Load parameters for all steps.
- Load the data immediately if starting from an intermediate
step; otherwise, just load the raw headers and defer loading
the data from the FITS files.
After this step, the input attribute is populated as required
for the first pipeline step in the recipe.
Parameters
----------
data : list of str or str
Input file paths to load.
param_class : class, optional
Parameters to instantiate, if not FLITECAMParameters.
"""
# imports for this step
from sofia_redux.calibration.pipecal_config import pipecal_config
from sofia_redux.instruments.flitecam.getcalpath import getcalpath
from sofia_redux.toolkit.utilities.fits import getheader
# call the parent method to initialize
# reduction variables
Reduction.load(self, data)
# read the first FITS header and use to configure reduction
self.basehead = getheader(self.raw_files[0])
self.calres = getcalpath(self.basehead)
log.debug('Full configuration:')
for key, value in self.calres.items():
log.debug(' {}: {}'.format(key, value))
# get product type to determine recipe
intermediate = False
prodtype = self.basehead.get('PRODTYPE', default='UNKNOWN')
# get remaining recipe for input prodtype
if prodtype in self.prodtypes:
pidx = self.prodtypes.index(prodtype)
self.recipe = self.recipe[pidx + 1:]
if len(self.recipe) == 0:
msg = f"No steps to run for prodtype '{prodtype}'."
log.error(msg)
raise ValueError(msg)
if str(prodtype).strip().upper() != 'UNKNOWN':
intermediate = True
# read in the pipecal configuration
if self.calres['name'] == 'IMA':
self.cal_conf = pipecal_config(self.basehead)
log.debug('Full pipecal configuration:')
for key, value in self.cal_conf.items():
log.debug(' {}: {}'.format(key, value))
if param_class is None: # pragma: no cover
# this option is not currently used
self.parameters = FLITECAMParameters(
config=self.calres,
pipecal_config=self.cal_conf)
else:
self.parameters = param_class(
config=self.calres,
pipecal_config=self.cal_conf)
# if not starting from raw data, load the files in
# immediately
if intermediate:
self.load_fits(intermediate=True)
else:
# just load headers
self.input = []
for datafile in self.raw_files:
self.input.append(getheader(datafile))
def _load_raw_data(self, datafile):
"""
Robustly read raw FLITECAM data.
Parameters
----------
datafile : str
Input filename.
Returns
-------
fits.HDUList
Flux and error data, as a FITS HDU list.
"""
from sofia_redux.instruments.flitecam.readfits import readfits
hdul = readfits(datafile)
return hdul
[docs]
def correct_linearity(self):
"""
Correct flux for nonlinearity.
Also calculates the error on the flux, after linearity
correction.
"""
from sofia_redux.instruments.flitecam.lincor import lincor
# get parameters
param = self.get_parameter_set()
saturation = param.get_value('saturation')
linfile = param.get_value('linfile')
if os.path.isfile(linfile):
log.info(f'Using linearity file {linfile}')
else:
raise ValueError('No linearity file provided.')
if str(saturation).strip() == '':
saturation = None
outdata = []
for i, hdul in enumerate(self.input):
log.info('')
log.info(f"Input: {hdul[0].header.get('FILENAME', 'UNKNOWN')}")
result = lincor(hdul, linfile, saturation=saturation)
outname = self.update_output(
result, self.filenum[i], self.prodtypes[self.step_index])
# save if desired
if param.get_value('save'):
self.write_output(result, outname)
outdata.append(result)
self.input = outdata